JD-1020 infusion sphygmomanometer

JD-1020 infusion sphygmomanometer

The full name of infusion sphygmomanometer is infusion pressurization bag with sphygmomanometer.
Infusion sphygmomanometer is used as a medical product in emergency case.
It is used to speed up the infusion speed with pressure method for the emergency patients who need infusion of medicine liquid or plasma with increased amount at higher speed.
For example, in the course of the intervention, because the vagus nerve reflex of some patients, dizziness, nausea, sweating, heart rate slowing down, blood pressure dropping to an extremely low level is likely to happen. If there is not a timely rescue, patients will fall into danger. Infusion sphygmomanometer is used as an effective instrument to save lives and reduce the labor intensity of doctors and nurses.

Main Technical data of infusion sphygmomanometer:

1. 0-400mmHg gauge
2. The gauge is integrated with air bulb
3. Air tightness of infusion bag: The infusion bag shall have good air tightness and there shall be no leakage in the usage of 3 hours.
4. The hanging ring shall stand weight of 1kg.

Advantages of Jianda infusion sphygmomanometer:

1.0-400mmHg gauge can help read and control the pressure in a larger scope than normal 0-300mmHG gauge.
2. Air bulb is connected with gauge and so users can press the bulb with one hand and check the pressure shown in the gauge. Another hand of the user is free for others, which is important especially in emergent cases.

Usage of infusion sphygmomanometer:

1. Put the plasma bag or infusion bag inside the infusion pressurization bag. Put the hanging rope of plasma bag or infusion bag through the hanging ring of infusion pressurization bag and fix it. Hang it on the transfusion shelf.
2. Inflate the infusion pressurization bag with bulb.
3. The speed and amount of infusion can be adjusted by the pressure of infusion pressurization bag. The pressure indicated on the dial of the gauge help users adjust pressure correctly. When the pressure is proper, fix the air release valve by rotating the air release valve clockwise.
4.When the infusion is finished, release the air inside the air bladder by rotating the air release valve anticlockwise.
5. Repeat the above for another time’s infusion.

Special suggestion about infusion pressurization bag:
This product is only used for one patient so as to avoid cross infection.